5–14 Quartus II Version 3.0 Altera Corporation
Perform the Standard Tests High-Speed Development Kit, Stratix GX Edition User Guide
Source Synchronous HM-Zd Interface (Stratix GX HM-Zd SPI 4.2)
For this test, perform the following steps in the Programmer.
1. Change the programming file for the Stratix GX device to
GX40_SS_HMZd.sof. Wait until the checksum field is updated.
2. Turn on the Program/Configure option for the Stratix GX device.
Figure 5–17 shows the Programmer after you have done these steps.
Figure 5–17. Quartus II Programmer for the Source-Synchronous HM-ZdTest
3. Click Start. When configuration is complete, the GX_CONF_DONE
(D7) LED illuminates.
4. Press the reset pushbutton switch (GX_CLR).
5. Press the start pushbutton switch (Stratix_GX_PB_0). Several LEDs
illuminate.
● LED0 is the high-speed data and control signal match LED. If it
illuminates, the test is successful.
● LED1 indicates that the GX device has received the data.
● LED2 indicates a per channel match. This LED is used for the per
channel feature.
● LED3 indicates that the test has started.
● LED4 is the match LED for the low-speed control signals.
● LED5 is the error indicator.
Commentaires sur ces manuels