Vue de la page 40
Altera Corporation 2–23
January 2005 Stratix GX Transceiver User Guide
Stratix GX Analog Description
Figure 2–15. MegaWizard Plug-In Manager - ALTGXB (Page 3 of 7) - Receiver (1) Note (1)
Note to Figure 2–15:
(1) Enable run length violation circuit. If enabled, the optional output pin rx_rlv pin is available and pulses high
when the specified run length is violated. In 8-bit or 16-bit mode, set the run length threshold from 4 to 124 in steps
of 4. In 10-bit and 20-bit mode, or if using 8b10b, set the run length threshold from 5 to 160 in steps of 5.