Vue de la page 630
VHDL Tutorials
Verifying a Slave DUT
Mentor VIP AE AXI3/4 User Guide, V10.2b
611
September 2013
Example 11-4. Write Burst Transaction Creation and Execution
-- Write data burst length of 7 to start address 16.
create_write_transaction(16, 7, tr_id, index, axi_tr_if_0(index));
data_words(31 downto 0) := x"ACE0ACE1";
set_data_words(data_words, 0, tr_id, index, axi_tr_if_0(index));
data_words(31 downto 0) := x"ACE2ACE3";
set_data_words(data_words, 1, tr_id, index, axi_tr_if_0(index));
data_words(31 downto 0) := x"ACE4ACE5";
set_data_words(data_words, 2, tr_id, index, axi_tr_if_0(index));
data_words(31 downto 0) := x"ACE6ACE7";
set_data_words(data_words, 3, tr_id, index, axi_tr_if_0(index));
data_words(31 downto 0) := x"ACE8ACE9";
set_data_words(data_words, 4, tr_id, index, axi_tr_if_0(index));
data_words(31 downto 0) := x"ACEAACEB";
set_data_words(data_words, 5, tr_id, index, axi_tr_if_0(index));
data_words(31 downto 0) := x"ACECACED";
set_data_words(data_words, 6, tr_id, index, axi_tr_if_0(index));
data_words(31 downto 0) := x"ACEEACEF";
set_data_words(data_words, 7, tr_id, index, axi_tr_if_0(index));
for i in 0 to 7 loop
set_write_strobes(15, i, tr_id, index, axi_tr_if_0(index));
end loop;
set_write_data_mode(AXI_DATA_WITH_ADDRESS, tr_id, index,
axi_tr_if_0(index));
execute_transaction(tr_id, index, axi_tr_if_0(index));
In the complete Master Test Program, a subsequent write data burst transaction has lane 0 of the
first data beat of the burst configured to be invalid, by setting the least significant bit of the
write_strobes[0] field to zero by passing in the value of 14. See set_write_strobes() for more
details.
set_write_strobes(14, 0, tr_id, index, axi_tr_if_0(index));
See the VHDL AXI4 Master BFM Test Program code listing for details.
Read Burst Transaction Creation and Execution
The code excerpt in Example 11-5 reads the first two data beats from the data burst that has
been previously written into the slave memory. The call to create_read_transaction() procedure
creates the read burst transaction by providing the start address and burst length arguments. The
actual length of the burst on the protocol signals is 1+1=2.
Note
The burst length argument passed to the create_read_transaction() procedure is 1 less
than the number of transfers (beats) in the burst. This aligns the burst length argument
value with the value placed on the ARLEN protocol signals.