VHDL AXI3 and AXI4 Monitor BFMs
get_write_data_phase()
September 2013
get_write_data_phase()
This blocking procedure gets a write data phase that is uniquely identified by the transaction_id
argument previously created by the create_monitor_transaction() procedure. The
get_write_data_phase() sets the data_beat_done array index element to 1 when the phase
completes. If this is the last data phase of the burst then it returns the last argument set to 1.
Prototype
-- * = axi| axi4
-- ** = AXI | AXI4
procedure get_write_data_phase
(
transaction_id : in integer;
index : in integer; --optional
last : out integer;
bfm_id : in integer;
path_id : in *_path_t; --optional
signal tr_if : inout *_vhd_if_struct_t
);
Arguments
transaction_id Transaction identifier. Refer to “Overloaded Procedure Common
Arguments” on page 203 for more details.
index (Optional) Data phase (beat) number.
last Last data phase (beat) of the burst:
0 = data burst not complete
1 = data burst complete
bfm_id BFM identifier. Refer to “Overloaded Procedure Common Arguments”
on page 203 for more details.
path_id (Optional) Parallel process path identifier:
**_PATH_0
**_PATH_1
**_PATH_2
**_PATH_3
**_PATH_4
Refer to “Overloaded Procedure Common Arguments” on page 203 for
more details.
tr_if Transaction signal interface. Refer to “Overloaded Procedure Common
Arguments” on page 203 for more details.
Returns