7–30 Chapter 7: Software Interface
HDLC Registers
CPRI MegaCore Function December 2013 Altera Corporation
User Guide
Table 7–74. HDLC_RX_DATA_WAIT—HDLC Rx Data with Wait-State Insertion—Offset: 0x318
Field Bits Access Function Default
rx_data
[31:0] RO
HDLC Rx frame data. If the HDLC receiver module takes HDLC data
from this register, it inserts wait states on the HDLC channel until
data is ready, unless the CPU times out the operation.
1'h0
Table 7–75. HDLC_TX_CONTROL—HDLC Tx Control—Offset: 0x31C
Field Bits Access Function Default
RSRV
[31:4] UR0 Reserved.
28'h0
tx_length
[3:2] RW
Length of the final word in the packet. Values are:
00: 1 valid byte
01: 2 valid bytes
10: 3 valid bytes
11: 4 valid bytes
This field is valid when the
tx_eop
bit is asserted.
1’h0
tx_discard
[1] WO
Indicates that the HDLC transmitter module should discard the
current HDLC Tx frame.
1'h0
tx_eop
[0] RW
Indicates that the next data word to be written to the
HDLC_TX_DATA
or
HDLC_TX_DATA_WAIT
register contains the end-of-packet byte for
this Tx packet.
1’h0
Table 7–76. HDLC_TX_DATA—HDLC Tx Data—Offset: 0x320
Field Bits Access Function Default
tx_data
[31:0] RW
HDLC Tx frame data. If the HDLC transmitter module writes HDLC
data to this register, if data is not ready when the module expects it,
the HDLC transmitter module aborts the packet.
1'h0
Table 7–77. HDLC_TX_DATA_WAIT—HDLC Tx Data with Wait-State Insertion—Offset: 0x324
Field Bits Access Function Default
tx_data
[31:0] RW
HDLC Tx frame data. If the HDLC transmitter module writes HDLC
data to this register, it waits until data is ready, unless the CPU times
out the operation.
1'h0
Table 7–78. HDLC_RX_EX_STATUS—HDLC Rx Additional Status—Offset: 0x328
Field Bits Access Function Default
RSRV
[31:7] UR0 Reserved.
25'h0
CRC_error
[6] RC Indicates that an HDLC frame with a CRC error was received.
1'h0
RSRV
[5:0] UR0 Reserved.
6'h0