2–60 Chapter 2: Board Components
Memory
Stratix V Advanced Systems Development Board January 2014 Altera Corporation
Reference Manual
Y8
MOSYS1_QBTX_N3
1.4-V PCML AD1 Transceiver input
AB7
MOSYS1_QBTX_N4
1.4-V PCML AB1 Transceiver input
Y6
MOSYS1_QBTX_N5
1.4-V PCML Y1 Transceiver input
AB5
MOSYS1_QBTX_N6
1.4-V PCML V1 Transceiver input
Y4
MOSYS1_QBTX_N7
1.4-V PCML T1 Transceiver input
AA11
MOSYS1_QBTX_P0
1.4-V PCML AK2 Transceiver input
W10
MOSYS1_QBTX_P1
1.4-V PCML AH2 Transceiver input
AA9
MOSYS1_QBTX_P2
1.4-V PCML AF2 Transceiver input
W8
MOSYS1_QBTX_P3
1.4-V PCML AD2 Transceiver input
AA7
MOSYS1_QBTX_P4
1.4-V PCML AB2 Transceiver input
W6
MOSYS1_QBTX_P5
1.4-V PCML Y2 Transceiver input
AA5
MOSYS1_QBTX_P6
1.4-V PCML V2 Transceiver input
W4
MOSYS1_QBTX_P7
1.4-V PCML T2 Transceiver input
F21
MOSYS1_RBIAS_0N
1.5-V CMOS Calibration resistor
E21
MOSYS1_RBIAS_0P
1.5-V CMOS Calibration resistor
F1
MOSYS1_RBIAS_1N
1.5-V CMOS Calibration resistor
E1
MOSYS1_RBIAS_1P
1.5-V CMOS Calibration resistor
M20
MOSYS1_READYN
1.5-V CMOS K15 Device ready
Y22
MOSYS1_REFCLK_N
LVDS Input reference clock
W22
MOSYS1_REFCLK_P
LVDS Input reference clock
M22
MOSYS1_RESETN_IN
1.5-V CMOS R15 Active low reset
P1
MOSYS1_SPI_SCLK
1.5-V CMOS D17 SPI slave clock
T1
MOSYS1_SPI_SDI
1.5-V CMOS C19 SPI data in or command
R2
MOSYS1_SPI_SDO
1.5-V CMOS F19 SPI data out
U2
MOSYS1_SPI_SS
1.5-V CMOS G19 SPI slave select, active low
H9
MOSYS1_VDD_KELVIN
1.0-V VDD monitor point
H8
MOSYS1_VSS_KELVIN
GND VSS monitor point
FPGA2 MoSys (U14)
G20
MOSYS2_AMON_0
1.5-V CMOS Analog monitor
B1
MOSYS2_AMON_1
1.5-V CMOS Analog monitor
P22
MOSYS2_CLKDIVIDE
1.5-V CMOS B16 REFCLK divider enable
A21
MOSYS2_CMDARX_N0
1.4-V PCML AG3 Transceiver output
C20
MOSYS2_CMDARX_N1
1.4-V PCML AE3 Transceiver output
A19
MOSYS2_CMDARX_N2
1.4-V PCML AC3 Transceiver output
C18
MOSYS2_CMDARX_N3
1.4-V PCML AA3 Transceiver output
A17
MOSYS2_CMDARX_N4
1.4-V PCML W3 Transceiver output
C16
MOSYS2_CMDARX_N5
1.4-V PCML U3 Transceiver output
A15
MOSYS2_CMDARX_N6
1.4-V PCML R3 Transceiver output
C14
MOSYS2_CMDARX_N7
1.4-V PCML N3 Transceiver output
Table 2–27. MoSys MSR576 Interface Pin Assignments, Signal Names and Functions (Part 3 of 5)
Board Reference Schematic Signal Name I/O Standard
Stratix V GX FPGA
Device Pin Number
Description