Chapter 3: Functional Description—ALTMEMPHY (nonAFI) 3–11
ALTMEMPHY Signals
© January 2010 Altera Corporation External Memory PHY Interface (ALTMEMPHY) (nonAFI) Megafunction User Guide
The ports in Table 33 exists for all DDR2/DDR SDRAM variations.
aux_full_rate_clk output 1 A copy of the mem_clk_2x signal that you can use in
other parts of your design.
Note to Table 3–2:
(1) Refer to Figure 4–3 for the reset mechanism in Arria GX, Cyclone III, Stratix II and Stratix II GX devices.
Table 3–2. Clock and Reset Signals for DDR2/DDR SDRAM—nonAFI (Note 1) (Part 2 of 2)
Signal Name Type Width Description
Table 3–3. PLL Reconfiguration Signals for DDR2 and DDR SDRAM—nonAFI
Signal Name Type Width Description
pll_reconfig_
enable
input 1 Allows access to the PLL reconfiguration block. Hold this
signal low in normal operation. While the ALTMEMPHY is held
in reset (via the soft_reset_n signal), and the
reset_request_n signal is 1, it is safe to reconfigure the
PLL. To reconfigure the PLL, set this signal to 1 and use the
other pll_reconfig signals to access the PLL. When
finished reconfiguring, set this signal to 0, and then set the
soft_reset_n signal to 1 to bring the ALTMEMPHY out of
reset. For this signal to work, the
PLL_RECONFIG_PORTS_EN parameter must be set to
TRUE.
pll_reconfig_
write_param
input 1 For more information, refer to the Phase-Locked Loop
(ALTPLL_RECONFIG) User Guide.
pll_reconfig_read
_param
input 1 For more information, refer to the Phase-Locked Loop
(ALTPLL_RECONFIG) User Guide.
pll_reconfig input 1 For more information, refer to the Phase-Locked Loop
(ALTPLL_RECONFIG) User Guide.
pll_reconfig_
counter_type
input 4 For more information, refer to the Phase-Locked Loop
(ALTPLL_RECONFIG) User Guide.
pll_reconfig_
counter_param
input 3 For more information, refer to the Phase-Locked Loop
(ALTPLL_RECONFIG) User Guide.
pll_reconfig_data
_in
input 9 For more information, refer to the Phase-Locked Loop
(ALTPLL_RECONFIG) User Guide.
pll_reconfig_soft
_reset_en_n
input 1 The asynchronous reset input to the PLL reconfiguration
block. This reset causes a PLL reconfiguration block reset and
holds the reset if the ALTMEMPHY megafunction in reset while
the signal is low. This port only exists in the DDR2/DDR
SDRAM variation for Arria GX, Stratix II, and Stratix II GX
devices.
pll_reconfig_busy output 1 For more information, refer to the Phase-Locked Loop
(ALTPLL_RECONFIG) User Guide.
pll_reconfig_data
_out
output 9 For more information, refer to the Phase-Locked Loop
(ALTPLL_RECONFIG) User Guide.
pll_reconfig_clk output 1 Synchronous clock to use for any logic accessing the PLL
reconfiguration interface.
pll_reconfig_
reset
output 1 Resynchronized reset to use for any logic accessing the PLL
reconfiguration interface.