Altera PHY IP Core Guide de l'utilisateur Page 592

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 626
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 591
Description
Controls the magnitude of the second pre-tap for pre-emphasis. The default value is 0.
Table 8-22: Available Options
Value Description
0 – 7 Magnitude 0 – 7
Note: Refer to Arria 10 Pre-Emphasis and Output Swing Settings spreadsheet for selecting legal pre-
emphasis and differential output voltage settings.
Assign To
TX serial data.
Syntax
set_instance_assignment -name XCVR_A10_TX_PRE_EMP_SWITCHING_CTRL_PRE_TAP_2T <value> -
to <tx_serial_data pin name>
Related Information
Arria 10 Pre-Emphasis and Output Swing Settings
XCVR_A10_TX_PRE_EMP_SWITCHING_CTRL_1ST_POST_TAP
Pin planner or Assignment Editor Name
Transmitter Pre-Emphasis First Post-Tap Magnitude
Description
Controls the magnitude of the first post-tap for pre-emphasis. The default value is 0.
Table 8-23: Available Options
Value Description
0 –25 Magnitude 0 –25
Note: Refer to Arria 10 Pre-Emphasis and Output Swing Settings spreadsheet for selecting legal pre-
emphasis and differential output voltage settings.
Assign To
TX serial data.
Syntax
set_instance_assignment -name XCVR_A10_TX_PRE_EMP_SWITCHING_CTRL_1ST_POST_TAP <value>
-to <tx_serial_data pin name>
8-18
XCVR_A10_TX_PRE_EMP_SWITCHING_CTRL_1ST_POST_TAP
UG-01143
2015.05.11
Altera Corporation
Analog Parameter Settings
Send Feedback