The following settings are observed in this example:
• The widths of the data inputs are all set to 8 bits
• The widths of the output ports are set to 16 bits
• The asynchronous clear (aclr) and clock enable (ena) signals are enabled
• Pipelining is enabled with an output latency of four clock cycles. Hence, the result is seen on the
output ports four clock cycles after the input data is available
The following figure shows the expected simulation results in the ModelSim-Altera software.
Figure 10-2: ALTMULT_COMPLEX Simulation Results
UG-01063
2014.12.19
Understanding the Simulation Results
10-9
ALTMULT_COMPLEX (Complex Multiplier)
Altera Corporation