Altera FIR Compiler Manuel d'utilisateur Page 39

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 76
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 38
Chapter 3: Parameter Settings 3–15
Specify the Architecture Specification
© May 2011 Altera Corporation FIR Compiler User Guide
1. For this tutorial, select Distributed Arithmetic: Fully Parallel Filter structure with
a pipeline level of 3.
Although these settings create a filter that uses a large number of logic cells,
increasing the pipeline level to 3 decreases the number of clock cycles to one,
thereby greatly increasing system performance. These settings are shown in
Figure 3–9.
2. Click Finish when you have set the architecture parameters.
Figure 3–9. Specify the Filter Architecture
Vue de la page 38