Signal Direction Description
vid_trs Output Clocked video time reference signal (TRS) signal. Used
with the SDI IP core to indicate a TRS, when asserted.
Note: For embedded synchronization mode only.
vid_v Output Clocked video vertical blanking signal. This signal is
asserted during the vertical blanking period of the video
stream.
Note: For separate synchronization mode only.
vid_v_sync Output Clocked video vertical synchronization signal. This signal
is asserted during the vertical synchronization period of
the video stream.
Note: For separate synchronization mode only.
Clocked Video Interface Control Registers
Table 4-20: Clocked Video Input Registers
Address Register Description
0 Control
Bit 0 of this register is the Go bit:
Setting this bit to 1 causes the CVI IP core start data
output on the next video frame boundary.
Bits 3, 2, and 1 of the Control register are the interrupt
enables:
Setting bit 1 to 1, enables the status update interrupt.
Setting bit 2 to 1, enables the stable video interrupt.
Setting bit 3 to 1, enables the synchronization outputs
(sof, sof_locked, refclk_div).