Altera SerialLite II Protocol Manuel d'utilisateur Page 39

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 84
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 38
Altera Corporation 39
SerialLite II Protocol Reference Manual
SerialLite II Specification
Figure 2–18. Link Management Packet Encapsulation
Link Management Packet Size
The link management packet has a fixed length of four bytes: a single byte
identifier followed by three bytes of payload.
Link Management Packet Payload Format
Table 2–18 shows the link management packet payload format using the
following parameters:
FC_TIME = Flow control time
ACK = Acknowledgement
NACK = Negative acknowledgement
SID = Segment identification
BIP-8 = 8 bits of bit interleaved parity
CLASS = Packet type class
Link Management Packet Type (LMP[23:20])
SerialLite II currently has the following management packets defined:
Flow Control Packets (Link Packet Type = 0x1); see detailed
description in “Flow Control (Optional)” on page 2–61.
Retry-on-Error Control Packets (Link Packet Type = 0x2); see
detailed description in “Retry-on-Error (Optional)” on page 2–64.
Link Management Packet Parameter (LMP[19:8])
This field contains parameters specific to the type of link management
packet. See “Flow Control (Optional)” on page 2–61 and “Retry-on-Error
(Optional)” on page 2–64 for details.
SLP Link Management Packet Payload
Table 2–18. Link Management Packet Format
Bits
[23:20] [19:16] [15:12] [11:8] [7:4] [3:0]
Type Parameter Description Protection
Flow control packet 0x1 CLASS FC_TIME BIP-8
Retry-on-error control packet 0x2 CLASS 0x0 SID BIP-8
Vue de la page 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 83 84

Commentaires sur ces manuels

Pas de commentaire