Altera Transceiver PHY IP Core Manuel d'utilisateur Page 574

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 702
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 573
Figure 16-12: Correct Connections
Transceiver
Reconfiguration
Controller
Transceiver Bank
3 Transceiver
Channels
3 Transceiver
Channels
10 GBASE-R
(unused)
(unused)
Custom
Custom
CMU PLL
S
to Embedded
Processor
Reconfig to
and from
Transceiver
Stratix V GX, GS, or GT Device
The following figure illustrates incorrect connections between two Transceiver Reconfiguration Control‐
lers and six transceiver channels. Two Transceiver Reconfiguration Controllers cannot access a single
reconfiguration interface because there is no arbitration logic to prevent concurrent access. The configu‐
ration shown results in a Quartus II compilation error.
Figure 16-13: Incorrect Connections
3 Transceiver
Channels
Transceiver Bank
3 Transceiver
Channels
Not Allowed
Custom
10 GBASE-R
10 GBASE-R
Custom
Custom
CMU PLL
Transceiver
Reconfiguration
Controller
S
to Embedded
Processor
Transceiver
Reconfiguration
Controller
S
to Embedded
Processor
Reconfig to
and from
Transceiver
Stratix V GX, GS, or GT Device
Merging TX PLLs In Multiple Transceiver PHY Instances
This section describes merging instances of the transceiver PHY.
UG-01080
2015.01.19
Merging TX PLLs In Multiple Transceiver PHY Instances
16-57
Transceiver Reconfiguration Controller IP Core Overview
Altera Corporation
Send Feedback
Vue de la page 573